F.1100

Back-up heater overheat cut-out tripped

Breakdown: the boiler is stopped

On a Vaillant aroTHERM VWL ../5 AS, aroTHERM plus VWL ../6 A, aroTHERM pure, aroTHERM Split plus, aroTHERM VWL ../7.1 A and ../8.1 A, aroTHERM VWL ../8.1 A Q, versoTHERM plus, recoCOMPACT exclusive or flexoTHERM/flexoCOMPACT exclusive heat pump, the overheat cut-out of the electric back-up heater has opened: the water there was too hot, for example because of too little flow or air in the heating circuit, an underfilled circuit or outside heat input. The electric back-up heater is switched off (on the aroTHERM pure and Split plus, legionella protection and outdoor unit defrosting are then no longer guaranteed), and the cut-out must be reset or replaced by a technician.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Call us: our technician must find the cause and reset the cut-out.

Does your boiler show F.1100?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.1100

The meaning depends on the boiler: find yours below.

F.1100

El. backup heater: overheat prot. open

Breakdown: the boiler is stopped aroTHERM VWL ../5 AS, aroTHERM plus VWL ../6 A, flexoTHERM exclusive VWF ../4, recoCOMPACT exclusive VWL ../5, versoTHERM plus VWL ../5
F.1100

Electric back-up heater overheating protection tripped

Breakdown: the boiler is stopped aroTHERM Split plus VWL ../8.2 AS, aroTHERM VWL ../7.1 A, ../8.1 A, aroTHERM VWL ../8.1 A Q, aroTHERM pure VWL ../7.2 AS

What our technician checks

  • Circulation of the heating circuit pump
  • The shut-off valves, opened if necessary
  • Unwanted heat input, to be reduced or stopped
  • The heating circuit strainers (clogging)
  • The overheat cut-out, to be reset, or replaced if its fuse element has blown
  • On a flexoTHERM: the automatic reset below 55 °C, then the reset key