Back-up heater phase failure
Breakdown: the boiler is stopped
On a Vaillant aroTHERM VWL ../5 AS, aroTHERM plus VWL ../6 A, aroTHERM pure, aroTHERM Split plus, aroTHERM VWL ../7.1 A and ../8.1 A, aroTHERM VWL ../8.1 A Q, versoTHERM plus, recoCOMPACT exclusive or flexoTHERM/flexoCOMPACT exclusive heat pump, the electric back-up heater has lost a phase: faulty back-up heater, loose electrical connections or mains voltage too low (on a flexoTHERM, the circuit breaker in the electrical box may also have tripped). The internal circuit breaker then switches the heat pump off, and legionella protection is not ensured while the back-up heater is out of order.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Call us: our technician must find the cause and reset the internal circuit breaker.
Does your boiler show F.1120?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.1120
The meaning depends on the boiler: find yours below.
El. backup heater: phase failure
Electric back-up heater phase failure
What our technician checks
- The electric back-up heater and its power supply
- The electrical connections
- The voltage at the back-up heater's electrical connection
- On a flexoTHERM: the circuit breaker in the electrical box, to be reset