Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Vaillant Fault code Vaillant
F.788

Heating circuit pump fault

Breakdown: the boiler is stopped

On a Vaillant aroTHERM VWL ../5 AS, aroTHERM plus VWL ../6 A, aroTHERM pure, aroTHERM Split plus, aroTHERM VWL ../7.1 A and ../8.1 A, aroTHERM VWL ../8.1 A Q, versoTHERM plus, recoCOMPACT exclusive or flexoTHERM/flexoCOMPACT exclusive heat pump, the electronics of the heating circulation pump have detected a fault (dry running, blockage, overvoltage or undervoltage): the pump has stopped and locked. This is a locking fault: a technician must find the cause and put the pump back into service.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.788?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

Vaillant

Choose a recognised installer

Ecowatt is a Vaillant installer: our group is on Vaillant's official list of installers.

The variants of code F.788

The meaning depends on the boiler: find yours below.

F.788

Heating circuit: pump fault

Breakdown: the boiler is stopped aroTHERM VWL ../5 AS, aroTHERM plus VWL ../6 A, recoCOMPACT exclusive VWL ../5, versoTHERM plus VWL ../5
F.788

The heating circuit pump reports an internal fault

Breakdown: the boiler is stopped aroTHERM Split plus VWL ../8.2 AS, aroTHERM VWL ../7.1 A, ../8.1 A, aroTHERM VWL ../8.1 A Q, aroTHERM pure VWL ../7.2 AS
F.788

Building circuit: pump fault

Breakdown: the boiler is stopped flexoTHERM exclusive VWF ../4

What our technician checks

  • Switching the heat pump off for at least 30 seconds
  • The plug-in connector on the circuit board
  • The operation of the pump
  • The heating circuit: water quantity and venting
  • The heating circuit strainers (clogging)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.