Compressor outlet temperature too high
Breakdown: the boiler is stopped
On a Vaillant aroTHERM VWL ../5 AS, aroTHERM plus VWL ../6 A, aroTHERM pure, aroTHERM Split plus, aroTHERM VWL ../7.1 A and ../8.1 A, aroTHERM VWL ../8.1 A Q, versoTHERM plus, recoCOMPACT exclusive or flexoTHERM/flexoCOMPACT exclusive heat pump, the temperature at the compressor outlet is above 130 °C (110 °C on an aroTHERM plus VWL ../6 A): operating limits exceeded, an electronic expansion valve that does not open properly, a clogged filter in the refrigerant circuit or too little refrigerant. This is a refrigerant circuit fault for a technician to check; depending on the fault, the system may keep heating in emergency mode.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.732?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.732
The meaning depends on the boiler: find yours below.
Compr. outlet temp. too high
Compressor outlet temperature too high
What our technician checks
- The compressor inlet and outlet sensors
- The condenser outlet temperature sensor (TT135)
- The electronic expansion valve: does it reach its end stop? (sensor and actuator test)
- The refrigerant quantity (technical data)
- The tightness of the refrigerant circuit
- The outdoor unit's service valves, which must be open
- The low-pressure sensor
- On an aroTHERM VWL ../8.1 A Q: the temperature difference before and after the refrigerant circuit filter (4 K at most), and the circuit board