Defrost time too long
Blocking: it retries by itself
On a Vaillant aroTHERM Split (VWL ../5 AS), aroTHERM plus (VWL ../6 A), versoTHERM plus or recoCOMPACT exclusive heat pump, defrosting the outdoor unit takes longer than 15 minutes: the heat pump restarts. If defrosting still takes too long after the third failed attempt, the heat pump switches off and shows fault F.741; it must then be checked whether the heating circuit supplies enough heat to defrost.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show S.283?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a recognised installer
Ecowatt is a Vaillant installer: our group is on Vaillant's official list of installers.
The variants of code S.283
The meaning depends on the boiler: find yours below.
Defrost duration too long
What our technician checks
- The heat the heating circuit can supply for defrosting
- The system water volume against the minimum volume, with a buffer tank in series on the return if needed
- The electric back-up heater, to be switched on to raise the return temperature