Brine outlet temperature too low

Blocking: it retries by itself

On a flexoTHERM exclusive or flexoCOMPACT exclusive heat pump, status code S.242, shown on the heat pump display, reports that the brine leaves the circuit that collects heat from the source too cold. To keep the evaporator from freezing, the compressor then stops for a while; if this happens three times in a row, a fault message appears and our technician needs to step in.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show S.242?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code S.242

The meaning depends on the boiler: find yours below.

S.242

Environment circuit: outlet temperature too low

Blocking: it retries by itself flexoTHERM exclusive VWF ../4

What our technician checks

  • The brine circuit flow and its pump (optimum difference 3 K)
  • The sensors, their plug-in contact and the harness, by resistance measurement
  • Bleeding the brine circuit
  • The appliance identification (DSN) and the antifreeze setting for the type of source