Compressor: starting current limiter fault
Breakdown: the boiler is stopped
On a flexoTHERM exclusive or flexoCOMPACT exclusive heat pump, F.1119 reports a fault of the compressor's starting current limiter: it is faulty or wrongly connected, or the mains voltage is too low. It is a fault: the heat pump no longer works normally, and our technician puts it back into operation once the cause is fixed.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.1119?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.1119
The meaning depends on the boiler: find yours below.
Compressor: inrush current limiter fault
What our technician checks
- All plug contacts
- The connection between the starting current limiter and the compressor
- The connection between the starting current limiter and the control board
- The starting current limiter, replaced if needed