Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Vaillant Fault code Vaillant
F.1119

Compressor: starting current limiter fault

Breakdown: the boiler is stopped

On a flexoTHERM exclusive or flexoCOMPACT exclusive heat pump, F.1119 reports a fault of the compressor's starting current limiter: it is faulty or wrongly connected, or the mains voltage is too low. It is a fault: the heat pump no longer works normally, and our technician puts it back into operation once the cause is fixed.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.1119?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.1119

The meaning depends on the boiler: find yours below.

F.1119

Compressor: inrush current limiter fault

Breakdown: the boiler is stopped flexoTHERM exclusive VWF ../4

What our technician checks

  • All plug contacts
  • The connection between the starting current limiter and the compressor
  • The connection between the starting current limiter and the control board
  • The starting current limiter, replaced if needed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.