Gas type setting not valid
Breakdown: the boiler is stopped
The boiler reports that its gas type setting is not valid: on the ecoTEC plus and ecoTEC exclusive CS/1 (from 2024) the gas type change was not completed, on the ecoTEC plus ../5-5 and the ecoCOMPACT VCC the coding resistor on the circuit board does not match the selected gas group. The boiler goes into fault mode and stops until the cause is fixed and it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.92?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.92
The meaning depends on the boiler: find yours below.
The gas type change was not completed correctly.
Incorrect gas type fault
Gas coding resistor fault
The boilers that show this code
What our technician checks
- The coding resistor on the circuit board (ecoTEC plus ../5-5, ecoCOMPACT VCC)
- The gas type check, to be redone with the correct gas group
- The setting of the gas change parameter D.156