+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Vaillant Fault code Vaillant
F.84

Implausible flow-return temperature difference

Breakdown: the boiler is stopped

The heating flow and return temperatures measured do not make sense: the sensors are badly fitted on their pipes or swapped. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.84?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.84

The meaning depends on the boiler: find yours below.

F.084

The temperature difference between the flow temperature sensor and the

Breakdown: the boiler is stopped VCW CS/1-5, VCW CS/1-7
F.84

NTC temp. diff. implausible fault

Breakdown: the boiler is stopped VC /8-5, VCW /5-3, VCW /5-5, VCW /5-7
F.84

Temperature difference error between the flow and return temperature sensors

Breakdown: the boiler is stopped VC 486/5-5
F.84

Fault: implausible temperature difference between the flow/return temperature sensors

Breakdown: the boiler is stopped VC 806/5-5, VCC /4, VUW /5-5

The boilers that show this code

What our technician checks

  • How the flow sensor is fitted on its pipe
  • How the return sensor is fitted on its pipe
  • Flow and return sensors swapped

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.