Temperature does not rise at burner start

Breakdown: the boiler is stopped

When the burner starts, the flow and return sensors see no temperature rise, or too slow a rise: lack of water or pressure too low in the heating, or a sensor not touching its pipe properly. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Look at the heating water pressure on the display: if it is too low, top it up as the boiler's user manual explains.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.83?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.83

The meaning depends on the boiler: find yours below.

F.083

The temperature rise recorded by the flow temperature sensor or the sensor

Breakdown: the boiler is stopped VCW CS/1-5, VCW CS/1-7
F.83

NTC temperature variation fault

Breakdown: the boiler is stopped VC /8-5, VCW /5-3, VCW /5-5, VCW /5-7
F.83

Temperature variation fault of the flow and/or return temperature sensor

Breakdown: the boiler is stopped VC 486/5-5, VC 806/5-5
F.83

Temperature variation fault on the flow and/or return temperature sensor

Breakdown: the boiler is stopped VUW /5-5
F.83

Temperature variation fault on the flow temperature sensor and/or the sensor

Breakdown: the boiler is stopped VCC /4

The boilers that show this code

What our technician checks

  • The system pressure and water quantity, topped up if needed
  • The flow sensor, properly placed on the flow pipe
  • The return sensor, properly placed on the return pipe
  • Sensor operation and connections
  • Leaks in the boiler and the system