Compressor hot gas thermostat tripped
Breakdown: the boiler is stopped
On a Vaillant aroTHERM VWL ../5 AS, aroTHERM plus VWL ../6 A, aroTHERM Split plus, aroTHERM VWL ../7.1 A and ../8.1 A, aroTHERM VWL ../8.1 A Q, versoTHERM plus or recoCOMPACT exclusive heat pump, the hot gas thermostat has switched the heat pump off because the refrigerant circuit was too hot (above 130 °C, or 110 °C on an aroTHERM plus VWL ../6 A). It tries to restart after waiting 5, then 30 minutes, and this fault is shown after three failed attempts; on an aroTHERM VWL ../8.1 A Q, it locks out if the fault returns within 24 hours.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.823?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.823
The meaning depends on the boiler: find yours below.
Hot gas thermal cut-out open
Compressor temperature switch tripped
What our technician checks
- The electronic expansion valve
- The refrigerant circuit strainer (filter), replaced if necessary
- On an aroTHERM VWL ../8.1 A Q: the temperature difference before and after the filter (4 K at most) and the refrigerant quantity
- On an aroTHERM VWL ../8.1 A Q: the circuit board, replaced if faulty
- For a fault in refrigerant circuit components: the manufacturer's service team