Inverter mains voltage out of tolerance
Breakdown: the boiler is stopped
On a Vaillant aroTHERM VWL ../5 AS, aroTHERM plus VWL ../6 A, aroTHERM pure, aroTHERM Split plus, aroTHERM VWL ../7.1 A and ../8.1 A, aroTHERM VWL ../8.1 A Q, versoTHERM plus or recoCOMPACT exclusive heat pump, the mains voltage supplying the inverter is missing or wrong (it must be between 195 V and 253 V), for example during a cut by the energy supplier. This is a power supply fault for a technician to check; depending on the fault, the system may keep heating in emergency mode.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.818?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.818
The meaning depends on the boiler: find yours below.
Inverter fault: mains voltage
The inverter mains voltage is absent or outside the tolerance range.
What our technician checks
- The mains voltage, between 195 V and 253 V, corrected if necessary
- On an aroTHERM VWL ../8.1 A Q: briefly cutting the power to restart it
- On an aroTHERM VWL ../8.1 A Q: the circuit board, replaced if faulty