Brine circuit pressure switch open
Breakdown: the boiler is stopped
On a flexoTHERM exclusive or flexoCOMPACT exclusive heat pump, F.787 reports that the pressure switch of the brine circuit (which draws heat from the ground, the outdoor air or the groundwater) has opened: the brine pressure has dropped (leak or air pocket), or the pressure switch, its wiring or fuse T4 is at fault; large fluctuations in the mains voltage can also trigger this message. This pressure switch, sometimes required in drinking water protection zones, shuts down the refrigerant circuit when the pressure is too low: the heat pump stops heating until our technician has fixed the fault.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Read the brine circuit pressure on the heat pump display (System monitor menu, brine circuit pressure). To top up the brine, call us.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.787?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.787
The meaning depends on the boiler: find yours below.
Environment circuit: pressure switch open
What our technician checks
- Leaks in the brine circuit
- Topping up the brine (or water) and bleeding the circuit
- The screw contact on the circuit board
- The pressure switch, checked and replaced if needed
- The wiring between X110B and X110, or between X110A and X110
- Fluctuations in the mains voltage
- Fuse T4, replaced if needed