4-way valve in the wrong position
Breakdown: the boiler is stopped
On an aroTHERM, versoTHERM plus or recoCOMPACT exclusive heat pump, the 4-way valve of the refrigerant circuit is not in the expected position: in heating mode the flow water is colder than the return water, because of an electrical or mechanical problem with the valve or a temperature sensor that reads wrongly. This is a fault: the heat pump no longer works normally (depending on the fault, it may keep running in emergency mode) and our technician has to find the cause.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.755?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.755
The meaning depends on the boiler: find yours below.
Fault: incorrect 4-way valve position
The 4-way valve is not in the expected position.
What our technician checks
- The 4-way valve: audible switching, in the sensor and actuator test
- The 4-way valve coil: correctly seated, and its voltage while switching
- The wiring harness and plug connections
- The electronic expansion valve temperature sensor (environment circuit)
- The finned tube heat exchanger sensor, compared with a contact thermometer (aroTHERM VWL ../2 A, ../3 A)
- The PCB, replaced if faulty (aroTHERM VWL ../8.1 A Q)