Vaillant Fault code Vaillant
F.75

Pump fault or lack of water

Breakdown: the boiler is stopped

When the pump starts, the boiler does not see the water pressure rise as expected: lack of water or air in the heating, pump stuck or faulty, or pressure sensor faulty. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Look at the heating water pressure on the display: if it is too low, top it up as the boiler's user manual explains.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.75?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.75

The meaning depends on the boiler: find yours below.

F.075

The pressure jump when the heating pump starts is insufficient.

Breakdown: the boiler is stopped VCW CS/1-5, VCW CS/1-7
F.75

No pressure jump detected when the pump starts

Breakdown: the boiler is stopped VCW /3, VSC /2
F.75

Pump fault/lack of water

Breakdown: the boiler is stopped VC /8-5, VCW /5-3, VCW /5-5, VCW /5-7
F.75

Fault: no pressure change detected when the pump starts

Breakdown: the boiler is stopped VC /4-5, VC 806/5-5, VUW /4-5, VUW /5-5
F.75

Pump fault / lack of water

Breakdown: the boiler is stopped VC 486/5-5
F.75

Pressure not detected when the water pump starts

Breakdown: the boiler is stopped VUW /3-5
F.75

Fault: no flow at pump start.

Breakdown: the boiler is stopped VCC /4

The boilers that show this code

What our technician checks

  • The system pressure, filling and venting
  • The heating pump: seizure, power supply, diagnostic D.149; replaced if faulty
  • The water pressure sensor, replaced if faulty
  • The adjustable bypass and the expansion vessels (the external one on the return)
  • The shut-off valves and thermostatic valves, to be opened
  • Leaks in the boiler and the system
  • The pump wiring harness (LIN cable)