Brine too cold for compressor start
Breakdown: the boiler is stopped
On a flexoTHERM exclusive or flexoCOMPACT exclusive heat pump, F.740 reports that the brine coming in from the brine circuit (which draws heat from the ground, the outdoor air or the groundwater) is too cold for the compressor to start in heating mode: below -28 °C with an air-to-brine collector, below -7 °C with a ground source, below 2 °C with groundwater. The compressor does not start while the temperature stays beyond that limit; if the code stays on, our technician checks the sizing of the brine circuit and the sensors.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.740?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.740
The meaning depends on the boiler: find yours below.