Fan module: overheat safety open
Breakdown: the boiler is stopped
On a flexoTHERM exclusive or flexoCOMPACT exclusive heat pump that draws its heat from the outdoor air, F.719 reports that the overheat safety of the defroster in the fan module has opened: flow too low or brine above 65 °C, defrosting outside its permitted range, or defrosting with the brine circuit not filled. The safety resets by itself once the temperature drops below 30 °C; if it went above 115 °C, its fuse element has blown and our technician must replace it.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.719?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.719
The meaning depends on the boiler: find yours below.
Vent. module: overheat. prot. open
What our technician checks
- Circulation by the brine circuit pump
- The shut-off valves, opened if needed
- Fuse F1 of the air-to-brine collector, replaced if needed
- The safety temperature limiter, replaced if its fuse element has blown