Brine circuit pump fault
Breakdown: the boiler is stopped
On a flexoTHERM exclusive or flexoCOMPACT exclusive heat pump, F.715 reports that the brine circuit pump has gone into fault: its electronics detected a problem (dry running, blockage, overvoltage or undervoltage) and switched it off and locked it; air in the circuit or brine that is too viscous can be the cause. It is a fault: the heat pump no longer works normally, and our technician puts it back into operation once the cause is fixed.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.715?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.715
The meaning depends on the boiler: find yours below.
Environment circuit: pump fault contact open
What our technician checks
- Switching the heat pump off at the mains for at least 30 seconds
- The plug contact on the circuit board
- The pump's operation
- Bleeding the brine circuit, and the air separator
- The brine mixing ratio, measured with a refractometer
- The dirt filter and strainer (fouling)