Brine too cold at the outlet
Breakdown: the boiler is stopped
On a flexoTHERM exclusive or flexoCOMPACT exclusive heat pump, F.710 reports that the brine temperature at the outlet of the brine circuit (which draws heat from the ground, the outdoor air or the groundwater) is too low: too little flow or air in that circuit, a faulty pump or temperature sensor, or a setting not carried over when the control board was replaced. It is a fault: the heat pump no longer works normally, and our technician puts it back into operation once the cause is fixed.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.710?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.710
The meaning depends on the boiler: find yours below.
Environment circuit: outlet temp. too low
What our technician checks
- The brine circuit flow and its pump's flow rate (optimum spread 3 K)
- The plug contacts on the circuit board and the wiring harness
- The temperature sensors, resistance-tested and replaced if needed
- Bleeding the brine circuit
- The device identification setting (DSN)
- The frost protection, set for the type of brine circuit