Unstable flame signal
Breakdown: the boiler is stopped
The boiler sees its flame fluctuate: air in the gas pipe, gas pressure too low, wrong air-gas ratio, blocked condensate drain, flue gas recirculation or broken ionisation current. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.68?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.68
The meaning depends on the boiler: find yours below.
The flame monitor reports an unstable flame signal.
Fault - unstable flame signal
Flame signal instability fault
The boilers that show this code
What our technician checks
- The dynamic gas pressure and the gas supply
- The air-gas ratio and the CO2 content of the flue gas
- The ionisation electrode, its cable and plug
- The gas injector
- The condensate drain (blockage)
- Flue gas recirculation and the flue gas path
- The circuit board, replaced if faulty