Gas flow outside expected values
Breakdown: the boiler is stopped
The boiler measures a gas flow that does not match what it expects: gas pressure too low, venturi filter wet or blocked, or flow sensor faulty. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.53?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.53
The meaning depends on the boiler: find yours below.
Gas valve assembly mass flow not in line with expected values
Gas flow sensor fault
The boilers that show this code
What our technician checks
- The dynamic gas pressure, at ignition and at full load
- The filter under the venturi cap (wet or blocked)
- The venturi's internal pressure test point, with no lubricant on the O-ring
- The gas valve regulation
- The mass flow sensor