Air and flue duct blocked
Breakdown: the boiler is stopped
The boiler detects that the air supply or the flue no longer flows properly: blocked duct, flue gas recirculating to the air intake, blocked condensate drain or, on the ecoCOMPACT VCC, a faulty fan. It is a fault: the boiler stops until a technician has been.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.35?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.35
The meaning depends on the boiler: find yours below.
The flue system duct is blocked.
Flue system duct error
Air supply/flue gas discharge fault
Air fault on the combustion unit
What our technician checks
- The air and flue duct along its whole length
- The air intake pipe
- The condensate drain, trap included, and the condensate pump
- The combustion chamber: electrodes, insulation, burner
- The dynamic gas pressure and the external gas pressure switch
- The ionisation electrode
- ecoCOMPACT VCC: the fan, its connector and the Hall sensor