Vaillant Fault code Vaillant
F.26

Gas valve fault

Breakdown: the boiler is stopped

The gas valve does not respond properly: its stepper motor (or its coil on the atmoTEC plus VUW /5-5) is disconnected or faulty, or the wiring or circuit board is at fault. It is a fault: the boiler can no longer control its gas and does not work normally until a technician has been.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.26?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.26

The meaning depends on the boiler: find yours below.

F.26

Fault §§ fuel valve faulty

Breakdown: the boiler is stopped VC /8-5, VCW /5-3, VCW /5-5, VCW /5-7
F.26

Gas valve stepper motor current implausible

Breakdown: the boiler is stopped VUW /3-5
F.26

Fault: gas valve assembly inoperative

Breakdown: the boiler is stopped VCC /4, VUW /5-5
F.26

Gas valve stepper motor current not plausible

Breakdown: the boiler is stopped VUW /4-5

The boilers that show this code

What our technician checks

  • The gas valve stepper motor: connector, cable, coils, voltage
  • The multi-pin connector
  • The wiring harness
  • The stepper motor, replaced if needed
  • The circuit board and the ionisation electrode

Related codes