Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
SIME Fault code SIME
67

Cascade header sensor fault

Blocking: it retries by itself

The cascade header sensor, in a cascade installation with the Murelle.HT, is faulty. This code needs no reset: our technician checks the configuration of the installation, its inputs and its outputs.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 67?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 67

The meaning depends on the boiler: find yours below.

67

Cascade header sensor fault

Blocking: it retries by itself Murelle.HT

What our technician checks

  • The configuration of the installation, its inputs and its outputs

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.