SIME Fault code SIME
06

No flame detected at the burner

Breakdown: the boiler is stopped

The boiler detects no flame at the burner, at the end of an ignition attempt or while running. It locks out for safety and only restarts after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas tap is open.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 06?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 06

The meaning depends on the boiler: find yours below.

06

No flame detected

Breakdown: the boiler is stopped Brava Slim HE, Edea HM, Murelle Revolution, Murelle.HT, Uniqa Revolution, Vera OF
06

FLAME LOCKOUT

Breakdown: the boiler is stopped Atlantis HM, Murelle HE R

What our technician checks

  • The electrode: its condition, and no contact with earth
  • The gas supply and gas pressure
  • The gas valve and the control board
  • The mesh filter on the gas valve pressure point, cleaned or replaced (Murelle Revolution)

Related codes