Water pressure too low in the system
Breakdown: the boiler is stopped
The water pressure in the heating circuit is too low and the boiler stops (below 0.5 bar on a Murelle HE R or an Atlantis HM). Once the water is topped up, an Edea HM, a Vera OF or a Brava Slim HE needs a reset and a Murelle Revolution a confirmation on the screen; the other models need no reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the pressure on the display or the gauge: when cold, it should be 1 to 1.2 bar (1 to 1.5 bar on a Murelle HE R or an Atlantis HM). If it is too low, open the filling tap (on an Atlantis HM 30 T, the filling connection) until it reaches that value, then close it again.
- On an Edea HM, a Vera OF or a Brava Slim HE, the boiler locks out: one reset is allowed, after topping up.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
- On a Murelle Revolution, confirm the topping up on the screen instead of resetting; on the other models, do not reset the boiler.
- Does the code stay on or come back? Do not take anything apart: call us.
- Do you often have to top up the water? There may be a leak: call us.