Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
SIME Fault code SIME
04

Domestic hot water sensor fault

Blocking: it retries by itself

The sensor that measures the domestic hot water temperature is faulty, open or short-circuited (on the T versions of a Murelle.HT, an Edea HM, a Vera OF or a Brava Slim HE, this code points to the return sensor). This code needs no reset: on an Atlantis HM, the boiler keeps running but no longer modulates its output for hot water.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 04?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 04

The meaning depends on the boiler: find yours below.

04

DHW sensor fault (return sensor fault for the "T" versions)

Blocking: it retries by itself Brava Slim HE, Edea HM, Murelle.HT, Vera OF
04

DHW circuit sensor fault

Blocking: it retries by itself Murelle Revolution, Uniqa Revolution
04

DHW SENSOR FAULT

Blocking: it retries by itself Atlantis HM

What our technician checks

  • The sensor connections
  • Whether the sensor works, replaced if needed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.