Gas valve open too long without a flame
Blocking: it retries by itself
On a Murelle Revolution, Edea HM, Uniqa Revolution, Vera OF or Brava Slim HE, the total time the gas valve has stayed open without a flame being detected has gone past its limit. This is not a code to reset: our technician looks for the cause, in the gas valve and the control board (Edea HM, Vera OF) or in water hammer on the domestic water side and abnormal requests from the room thermostat (Murelle Revolution, Uniqa Revolution, Brava Slim HE).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 44?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 44
The meaning depends on the boiler: find yours below.
Gas valve timer elapsed without flame
Total valve opening time without flame
What our technician checks
- The gas valve and the control board (Edea HM, Vera OF)
- Water hammer in the domestic water system, and an anti-hammer device if there is any
- Abnormal requests from the room thermostat