Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
SIME Fault code SIME
01

Flue gas thermostat tripped

Breakdown: the boiler is stopped

The flue gas thermostat has shut the boiler down: on a Vera OF, an open-chamber boiler, it checks that the flue gases are carried away properly and switches back on by itself after about 20 minutes; a Brava Slim HE shows the same code without further detail from the manufacturer. The flue gases may not be escaping properly: do not reset the boiler and call us straight away, even if it starts again by itself.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Do not reset the boiler: call us.

Does your boiler show 01?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 01

The meaning depends on the boiler: find yours below.

01

Flue gas thermostat

Breakdown: the boiler is stopped Brava Slim HE, Vera OF

What our technician checks

  • The flue duct, undamaged and gas-tight (Vera OF)
  • The combustion air opening of the room, 6 cm² per kW (Vera OF)
  • The flue gas thermostat, never disabled; if needed replaced with an original part refitted in its seat (Vera OF)
  • The diagnosis with Sime's assistance centre

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.