Flue gas thermostat tripped
Breakdown: the boiler is stopped
The flue gas thermostat has shut the boiler down: on a Vera OF, an open-chamber boiler, it checks that the flue gases are carried away properly and switches back on by itself after about 20 minutes; a Brava Slim HE shows the same code without further detail from the manufacturer. The flue gases may not be escaping properly: do not reset the boiler and call us straight away, even if it starts again by itself.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Do not reset the boiler: call us.
Does your boiler show 01?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 01
The meaning depends on the boiler: find yours below.
Flue gas thermostat
What our technician checks
- The flue duct, undamaged and gas-tight (Vera OF)
- The combustion air opening of the room, 6 cm² per kW (Vera OF)
- The flue gas thermostat, never disabled; if needed replaced with an original part refitted in its seat (Vera OF)
- The diagnosis with Sime's assistance centre