Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Junkers Fault code Junkers
C3

Flue gas escaping from the combustion chamber

Blocking: it retries by itself

The boiler has detected flue gas escaping from its combustion chamber and has stopped for safety (CeraclassExcellence ZWC and ZSC ..-3 MFK, connected to a chimney). It is a temporary stop: it restarts by itself after about 20 minutes, but if the code comes back often, the chimney needs improving or the boiler needs servicing.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Wait: the boiler restarts by itself after about 20 minutes.
  3. Smell flue gas in the room? Switch the boiler off, open doors and windows, get everyone out and call us.
  4. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show C3?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code C3

The meaning depends on the boiler: find yours below.

C3

Flue gas escaping from the combustion chamber

Blocking: it retries by itself ZWC-3

The boilers that show this code

What our technician checks

  • The heat exchanger, for fouling

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.