Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Junkers Fault code Junkers
AA

Hot water and heating temperatures too far apart

Breakdown: the boiler is stopped

On a CeraclassExcellence ZWC-3 the boiler measures too large a temperature gap between the domestic hot water and the heating: poor contact of the hot water sensor, a dirty or scaled plate heat exchanger, or a three-way valve that does not close properly while making hot water. It is a fault: the boiler stops and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show AA?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code AA

The meaning depends on the boiler: find yours below.

AA

Temperature difference between EC and CC too large

Breakdown: the boiler is stopped ZWC-3

The boilers that show this code

What our technician checks

  • The contact of the hot water sensor on the plate heat exchanger
  • The plate heat exchanger: dirt and scale
  • The three-way valve, which must close fully while hot water is being made

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.