Water pressure too high, switch or settings
Blocking: it retries by itself
On a Bluehelix HiTech RRT or a New Elite 60 the system water pressure is too high; on a Bluehelix Alpha the water pressure switch or pressure sensor is configured wrongly or reports a pressure out of range; on a Bluehelix Top RRT a circuit board parameter is set wrongly. The boiler stops temporarily and restarts by itself once the cause has gone; on a HiTech RRT, if the code comes back more than three times in 24 hours, it becomes lockout A26.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F40?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F40
The meaning depends on the boiler: find yours below.
Water pressure switch fault
Board parameter fault
Pressure sensor fault
Incorrect system water pressure
The boilers that show this code
What our technician checks
- The system pressure, brought back to 1 to 1.5 bar by partial draining (Bluehelix HiTech RRT), and the system (New Elite 60)
- The expansion vessel, recharged or replaced
- New Elite 60: the safety valve and the pressure sensor
- Bluehelix Alpha: the setting of parameter b04 (0 = pressure switch, default) and the pressure measured by the transducer
- Bluehelix Top RRT: the circuit board parameters, corrected if needed