Ferroli Fault code Ferroli
A01

The burner does not light

Breakdown: the boiler is stopped

The boiler tries to light its burner but detects no flame, for example because of a lack of gas or the ignition electrode. The boiler locks out for safety and only restarts after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the gas tap upstream of the boiler and the one at the gas meter are open.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show A01?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code A01

The meaning depends on the boiler: find yours below.

A01

The burner does not light

Breakdown: the boiler is stopped Bluehelix Alpha, Bluehelix HiTech RRT C, Bluehelix Top RRT K 50, Econcept
A01

Burner not lighting

Breakdown: the boiler is stopped Econcept 51 A

What our technician checks

  • The gas supply to the boiler, air purged from the pipes and the mains gas pressure
  • The ignition and detection electrode: wiring, position, scale; replaced if needed
  • The gas valve, replaced if needed
  • The condensate trap, cleaned if needed
  • The chimney, flue ducts, air inlet and terminals (blockage)
  • The burner calibration: full manual calibration (Bluehelix Alpha) or AUTO SETUP (Bluehelix HiTech RRT)