No flame after the ignition phase
Breakdown: the boiler is stopped
After the ignition phase the boiler detects no flame, for example because of the ionisation electrode, an unstable flame, a blocked flue or condensate trap (on an Econcept 51 A: six times in four minutes). The boiler locks out for safety and only restarts after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show A06?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code A06
The meaning depends on the boiler: find yours below.
No flame after the ignition phase
No flame after the ignition phase (6 times in 4 min)
What our technician checks
- The ionisation electrode: position and deposits; replaced if needed
- The burner
- The chimney, flue ducts, air inlet and terminals (blockage)
- The condensate trap, cleaned if needed
- The calibration: full manual (Bluehelix Alpha) or AUTO SETUP (Bluehelix HiTech RRT)
- Econcept 51 A: the gas valve Offset setting at minimum output
- Bluehelix HiTech RRT: the mains gas pressure