Ferroli Fault code Ferroli
A02

Flame signal with burner off, or safety thermostat

Breakdown: the boiler is stopped

On a Bluehelix Alpha, Top RRT, HiTech RRT or an Econcept 51 A, the boiler detects a flame while the burner is off, a sign of a fault in the electrode or the circuit board; on an Econcept 25, 35, 50 or Kombi 35, the safety thermostat has tripped, for example because water no longer circulates in the system. In both cases the boiler locks out for safety and only restarts after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show A02?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code A02

The meaning depends on the boiler: find yours below.

A02

Flame present with the burner off

Breakdown: the boiler is stopped Bluehelix Alpha, Bluehelix HiTech RRT C, Bluehelix Top RRT K 50, Econcept 51 A
A02

Safety thermostat tripped

Breakdown: the boiler is stopped Econcept

What our technician checks

  • The ionisation electrode wiring, and the electrode or its cable shorted to earth
  • The condition of the electrode
  • The condensate trap (Bluehelix)
  • The circuit board
  • Econcept 25, 35, 50, Kombi 35: the position and operation of the flow sensor
  • Econcept 25, 35, 50, Kombi 35: the circulation pump, the bypass and the system valves

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.