Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Bosch Fault code Bosch
F7

Flame detected while the boiler is off

Breakdown: the boiler is stopped

The boiler detects a flame while its burner is off: a dirty or cracked electrode, moisture on the circuit board or the flue is at fault; on a Condens 7000iW, F7 328 means something else, an interrupted mains voltage. It is a fault: the boiler stops and only starts again after a reset; F7 328, however, clears by itself once the power is back.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Code F7 328 on a Condens 7000iW: the boiler restarts by itself once the fault has cleared, do not reset it.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F7?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F7

The small number shown beside the code tells which.

F7

Flame is detected while the boiler is out of operation

Breakdown: the boiler is stopped Condens 3000 W
F7
228

Although the burner is off, flame is detected

Breakdown: the boiler is stopped GC7000iW
F7
328

Mains voltage interrupted

Blocking: it retries by itself GC7000iW

The boilers that show this code

What our technician checks

  • The electrode set: cracks, dirt, replaced if needed
  • The flue, cleaned or improved if needed
  • Moisture on the circuit board, dried if needed
  • For F7 328: the mains voltage

The same fault on other boilers

Recent boilers show alone the number older ones show beside the code.

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.