Viessmann Fault code Viessmann
F59

Outlet sensor open circuit or low voltage

Blocking: it retries by itself

On a Vitopend 100-W (WH1D combi version, A1JA) the hot water outlet temperature sensor is open-circuited: the boiler no longer makes domestic hot water. On a Vitodens One Base (200-W B2HF or B2KF, 222-F B2TF, 222-W B2LF), F.59 means the boiler's power supply voltage is too low: the burner is blocked, the internal pump stops and there is no more heating or hot water.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F59?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F59

The meaning depends on the boiler: find yours below.

F.59

Processor undervoltage

Blocking: it retries by itself Vitodens One Base
F59

Open circuit of the outlet temperature sensor (dual-function gas boiler)

Blocking: it retries by itself Vitopend 100-W WH1D
F59

Open circuit of the outlet temperature sensor

Blocking: it retries by itself Vitopend 100-W A1JA

What our technician checks

  • The hot water outlet temperature sensor (Vitopend 100-W)
  • Vitodens One Base: the appliance switched off for at least 2 minutes, then switched on again
  • Vitodens One Base: the mains voltage; if it is too low, the electricity distributor is informed
  • Vitodens One Base: the fan unit, replaced if the mains voltage is correct