Temperature sensor short-circuited
Blocking: it retries by itself
On a Vitopend 100-W (WH1D or A1JA) the boiler temperature sensor is short-circuited: the burner blocks and the boiler stops heating until the sensor is repaired. On a Vitodens One Base (200-W B2HF or B2KF, 222-F B2TF, 222-W B2LF), F.30 concerns the flow temperature sensor of the low loss header: the boiler keeps running, but regulates without that sensor.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F30?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F30
The meaning depends on the boiler: find yours below.
Short circuit of the low loss header sensor
Short circuit of the boiler temperature sensor
What our technician checks
- The boiler temperature sensor (Vitopend 100-W)
- Vitodens One Base: the « Low loss header » setting in the commissioning assistant
- Vitodens One Base: connection TS3 9 on the ADIO electronics module (EM-M1 or EM-P1 extension): plug, wires, corrosion, cables
- Vitodens One Base: the sensor's resistance (NTC 10 kΩ) compared with the curve