Viessmann Fault code Viessmann
0E

Flue gas monitor tripped

Blocking: it retries by itself

On a Vitopend 100-W connected to a chimney (WH1D or A1JA), the flue gas monitor has tripped: the flue gas is not leaving through the flue as it should. For safety the burner stops and stays blocked for 18 to 20 minutes before it can restart; if this happens 10 times within 24 hours, the boiler locks out and shows F6.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Can you smell flue gas? Switch the boiler off, air the room where it stands, close the doors to the living rooms and call us.
  3. Keep the air vents of the boiler room clear; a cooker hood or extractor fan running at the same time can draw the flue gas back in.
  4. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 0E?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 0E

The meaning depends on the boiler: find yours below.

0E

The flue gas monitoring has responded

Blocking: it retries by itself Vitopend 100-W A1JA, Vitopend 100-W WH1D

What our technician checks

  • The flue