Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Vaillant Fault code Vaillant
S.277

Heating circuit: pump fault

Blocking: it retries by itself

On a Vaillant aroTHERM Split (VWL ../5 AS), aroTHERM plus (VWL ../6 A), versoTHERM plus, recoCOMPACT exclusive or flexoTHERM exclusive heat pump, the heating circuit pump is not running: the heat pump switches off for 10 minutes, then restarts. If the pump still does not start after the third failed attempt, the heat pump switches off and shows fault F.788.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show S.277?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code S.277

The meaning depends on the boiler: find yours below.

S.277

Heating circuit: pump fault

Blocking: it retries by itself aroTHERM VWL ../5 AS, aroTHERM plus VWL ../6 A, recoCOMPACT exclusive VWL ../5, versoTHERM plus VWL ../5
S.277

Building circuit: pump fault

Blocking: it retries by itself flexoTHERM exclusive VWF ../4

What our technician checks

  • Switching the heat pump off for at least 30 seconds
  • The pump plug connection on the circuit board
  • The operation of the heating circuit pump
  • Venting the heating circuit
  • The circuit filter, not blocked (aroTHERM Split, aroTHERM plus)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.