Heating circuit: pump fault
Blocking: it retries by itself
On a Vaillant aroTHERM Split (VWL ../5 AS), aroTHERM plus (VWL ../6 A), versoTHERM plus, recoCOMPACT exclusive or flexoTHERM exclusive heat pump, the heating circuit pump is not running: the heat pump switches off for 10 minutes, then restarts. If the pump still does not start after the third failed attempt, the heat pump switches off and shows fault F.788.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show S.277?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code S.277
The meaning depends on the boiler: find yours below.
Heating circuit: pump fault
Building circuit: pump fault
What our technician checks
- Switching the heat pump off for at least 30 seconds
- The pump plug connection on the circuit board
- The operation of the heating circuit pump
- Venting the heating circuit
- The circuit filter, not blocked (aroTHERM Split, aroTHERM plus)