Heating water pressure low
Information: nothing to do
On a Vaillant aroTHERM VWL ../5 AS, aroTHERM plus VWL ../6 A, versoTHERM plus, recoCOMPACT exclusive or flexoTHERM/flexoCOMPACT exclusive heat pump, the water pressure in the heating circuit is low (below 0.7 bar), because of a leak, an air pocket or a faulty pressure sensor. This is a maintenance message: the heat pump is not in fault mode and keeps running normally, but if the pressure drops below 0.5 bar for more than a minute, fault F.22 is shown.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Read the water pressure on the display (menu, system monitor) and write it down.
- Call us: our technician will top up the heating water and look for the cause of the drop.
Nothing to do
This message belongs to the boiler's normal operation.
Call usChoose a recognised installer
Ecowatt is a Vaillant installer: our group is on Vaillant's official list of installers.
The variants of code M.32
The meaning depends on the boiler: find yours below.
Heating circ. water pressure low
Building circuit: low pressure
What our technician checks
- The heating circuit's tightness, topping up and venting
- The pressure sensor, its plug on the circuit board and the wiring harness, replaced if necessary