Compressor phase error (inverter)

Breakdown: the boiler is stopped

On an aroTHERM pro VWL ../7.1 A, aroTHERM plus VWL ../8.1 A, aroTHERM VWL ..5/8.1 A Q or aroTHERM perform heat pump, the inverter's internal diagnostics report a compressor phase error: wiring between the inverter and the mains (phase wrongly connected, loose connections), a faulty part inside the inverter, or a disturbance on the mains (voltage or frequency swings, power cuts). It is a fault: the heat pump no longer works normally and our technician needs to step in.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.764?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.764

The meaning depends on the boiler: find yours below.

F.764

The internal diagnostics of the inverter report a compressor phase error.

Breakdown: the boiler is stopped aroTHERM VWL ../7.1 A, ../8.1 A, aroTHERM VWL ../8.1 A Q

What our technician checks

  • The mains and compressor connection cables, undamaged and clicked in
  • The mains voltage, between 195 V and 253 V
  • The phases