Condensing temperature too high
Breakdown: the boiler is stopped
On a Vaillant aroTHERM VWL ../5 AS, aroTHERM plus VWL ../6 A, aroTHERM Split plus, aroTHERM VWL ../7.1 A and ../8.1 A, aroTHERM VWL ../8.1 A Q, versoTHERM plus, recoCOMPACT exclusive or flexoTHERM/flexoCOMPACT exclusive heat pump, the refrigerant's condensing temperature is too high for the compressor to run: when heating, the heating water is too hot, for example because of outside heat input, too little water flow or an overfilled refrigerant circuit. This is a refrigerant circuit fault for a technician to check; depending on the fault, the system may keep heating in emergency mode.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.737?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.737
The meaning depends on the boiler: find yours below.
Condensation temp. too high
The condensation temperature of the refrigerant circuit is too high.
What our technician checks
- Unwanted heat input, to be reduced or stopped
- The back-up heater: does it heat while set to Off in the sensor and actuator test?
- The electronic expansion valve: does it reach its end stop? (sensor and actuator test)
- The compressor outlet sensor, sensor TT135 at the condenser outlet and the high-pressure sensor
- The refrigerant quantity (overfilling)
- The outdoor unit's service valves, which must be open
- The air flow when cooling
- The heating pump and the heating circuit flow