Evaporation temperature too high
Breakdown: the boiler is stopped
On a Vaillant aroTHERM VWL ../5 AS, aroTHERM plus VWL ../6 A, aroTHERM Split plus, aroTHERM VWL ../7.1 A and ../8.1 A, aroTHERM VWL ../8.1 A Q, versoTHERM plus, recoCOMPACT exclusive or flexoTHERM/flexoCOMPACT exclusive heat pump, the evaporation temperature is too high for the compressor to run: when heating, the heat source is too warm or supplies too much heat (for example a fan running fast); when cooling, it is the heating water. This is a refrigerant circuit fault for a technician to check; depending on the fault, the system may keep heating in emergency mode.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.735?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.735
The meaning depends on the boiler: find yours below.
Evaporation temp. too high
Evaporation temperature too high
What our technician checks
- The system temperatures
- The refrigerant quantity (overfilling)
- The electronic expansion valve: does it reach its end stop? (sensor and actuator test)
- The evaporation temperature sensor, depending on the 4-way valve position
- The water flow when cooling and the air flow when heating
- On a flexoTHERM: unwanted heat input, to be reduced or stopped
- The compressor inlet sensor and the low-pressure sensor
- On an aroTHERM VWL ../8.1 A Q: the brine return temperature (below 30 °C) and the circuit board