Condensing temperature too low
Breakdown: the boiler is stopped
On a Vaillant aroTHERM VWL ../5 AS, aroTHERM plus VWL ../6 A, aroTHERM Split plus, aroTHERM VWL ../7.1 A and ../8.1 A, aroTHERM VWL ../8.1 A Q, versoTHERM plus, recoCOMPACT exclusive or flexoTHERM/flexoCOMPACT exclusive heat pump, the refrigerant's condensing temperature is too low: the water in the heating circuit is too cold, outside the operating range, or the refrigerant quantity is wrong (too little, or too much on an aroTHERM VWL ../8.1 A Q). This is a refrigerant circuit fault for a technician to check; depending on the fault, the system may keep heating in emergency mode.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.734?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.734
The meaning depends on the boiler: find yours below.
Condensation temp. too low
Condensation temperature too low
What our technician checks
- The electronic expansion valve: does it reach its end stop? (sensor and actuator test)
- The compressor inlet sensor
- The high-pressure and low-pressure sensors
- The refrigerant quantity (technical data) and tightness
- The 4-way valve: intermediate position or faulty switching
- The heating circuit pressure sensor
- On an aroTHERM VWL ../8.1 A Q: the return temperature (screed drying, cold building or cold cylinder?) and the circuit board
- On a versoTHERM plus or recoCOMPACT exclusive: unwanted heat input, to be reduced or stopped