Evaporation temperature too low
Breakdown: the boiler is stopped
On a Vaillant aroTHERM VWL ../5 AS, aroTHERM plus VWL ../6 A, aroTHERM Split plus, aroTHERM VWL ../7.1 A and ../8.1 A, aroTHERM VWL ../8.1 A Q, versoTHERM plus, recoCOMPACT exclusive or flexoTHERM/flexoCOMPACT exclusive heat pump, the refrigerant's evaporation temperature is too low: the heat source does not supply enough energy (too little air through the outdoor unit's heat exchanger, or no flow in a flexoTHERM's environment circuit), or the circuit is short of refrigerant. This is a refrigerant circuit fault for a technician to check; depending on the fault, the system may keep heating in emergency mode.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.733?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.733
The meaning depends on the boiler: find yours below.
Evaporation temp. too low
Evaporation temperature too low
What our technician checks
- The thermostatic valves in the heating circuit: suitable for cooling? (flow when cooling)
- Fouling of the fan unit
- The electronic expansion valve: does it reach its end stop? (sensor and actuator test)
- The compressor inlet sensor and the low-pressure sensor
- The refrigerant quantity
- On a flexoTHERM: the flow and sizing of the environment circuit
- On an aroTHERM VWL ../8.1 A Q: the temperature difference across the refrigerant circuit filter (4 K at most)
- On an aroTHERM VWL ../8.1 A Q: the circuit board, replaced if faulty