Communication with the outdoor unit lost
Breakdown: the boiler is stopped
On an aroTHERM VWL ..5/8.1 A Q or aroTHERM perform heat pump (VWZ AI /8 iQ module), communication with the outdoor unit is lost: a SystemLAN link that is unplugged, damaged, wrongly wired or of the wrong cable type, a faulty or unpowered SystemLAN switch, a cable too close to the power cables, or an outdoor unit without power or with a faulty circuit board. It is a fault: the heat pump no longer works normally and our technician needs to step in.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.6182?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a recognised installer
Ecowatt is a Vaillant installer: our group is on Vaillant's official list of installers.
The variants of code F.6182
The meaning depends on the boiler: find yours below.
Communication with the outdoor unit of the heat pump interrupted
What our technician checks
- The SystemLAN terminal strip wiring and its connectors, fully pushed in
- The IDC connector or SystemLAN cable, replaced if damaged
- One cable per connector, using the SystemLAN switch
- The cable type required by the manual
- The SystemLAN switch and its connector
- The distance between the SystemLAN cable and the power cables
- The outdoor unit's power supply
- The outdoor unit's circuit board