Primary circuit pressure too low
Breakdown: the boiler is stopped
On an aroTHERM VWL ..5/8.1 A Q or aroTHERM perform heat pump (VWZ AI /8 iQ module), the primary heating circuit water pressure is too low: a leak or air in the circuit, or an expansion vessel that is missing, too small, faulty or wrongly set. It is a fault: below the minimum pressure the heat pump stops, and our technician needs to find the cause.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.6104?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a recognised installer
Ecowatt is a Vaillant installer: our group is on Vaillant's official list of installers.
The variants of code F.6104
The meaning depends on the boiler: find yours below.
Primary heating circuit pressure too low
What our technician checks
- The primary circuit expansion vessel: fitted and large enough
- The expansion vessel pre-charge pressure, reset if needed
- The expansion vessel connection
- The expansion vessel, replaced if needed
- The heating circuit for leaks
- Refilling with water or glycol mix and bleeding with the venting program