Electronic expansion valve fault
Breakdown: the boiler is stopped
On an aroTHERM, versoTHERM plus or recoCOMPACT exclusive heat pump, the electronic expansion valve of the refrigerant circuit does not respond to its control: it is badly connected, the cable to its coil is broken or the cable insulation is damaged, or on the aroTHERM VWL ../8.1 A Q the PCB is faulty. This is a fault: the heat pump no longer works normally (depending on the fault, it may keep running in emergency mode) and our technician has to find the cause.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.582?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.582
The meaning depends on the boiler: find yours below.
EVD error
Electronic expansion valve fault
A control problem with the electronic expansion valve has been detected.
A connection fault of the expansion valve was detected.
What our technician checks
- The electronic expansion valve plug connections
- The electronic expansion valve coil, replaced if necessary
- The coil cable (break, insulation)
- The PCB, replaced if faulty (aroTHERM VWL ../8.1 A Q)