Too many resets or input S3 miswired
Breakdown: the boiler is stopped
This code does not mean the same on every boiler: on a Murelle.HT, a Murelle Revolution, an Edea HM, a Uniqa Revolution, a Vera OF or a Brava Slim HE, the boiler has reached the maximum number of consecutive resets; on a Murelle HE R or an Atlantis HM (installation 7), a sensor is connected to input S3 of the board instead of a potential-free contact. In the first case the boiler stays off; in the second it keeps running normally, but the solar board keeps only the collector frost protection.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- On a Murelle.HT, a Murelle Revolution, an Edea HM, a Uniqa Revolution, a Vera OF or a Brava Slim HE, do not reset the boiler again: it has already been reset too often.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 28?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 28
The meaning depends on the boiler: find yours below.
Maximum number of consecutive resets reached
Maximum number of consecutive resets
INPUT (S3) CONSISTENCY FAULT, SYSTEM 7 ONLY
What our technician checks
- Unlocking the board, no sooner than one hour after the last attempt
- Input S3 of the board: a potential-free contact, not a sensor (installation 7, Murelle HE R, Atlantis HM)